The kit is intended for rapidly extracting viral DNA/RNA from Swab,Saliva and other liquid samples. Realizes the high-throughput processing of parallel samples. The whole operation process is safe, convenient and no need for organic reagent. The extracted nucleic acids are highly purified and in quantity, can be widely used in the fields of diagnostics, genomics research, disease detection, food safety and forensic identification, etc.
Product Description:
The kit is intended for rapidly extracting viral DNA/RNA from Swab,Saliva and other liquid samples. Realizes the high-throughput processing of parallel samples. The whole operation process is safe, convenient and no need for organic reagent. The extracted nucleic acids are highly purified and in quantity, can be widely used in the fields of diagnostics, genomics research, disease detection, food safety and forensic identification, etc.
Features:
Rapid extraction — within 10 minutes
Safe and convenient — No need for organic reagent
Easy operation — Pre-filled design
Product Information:
Product Code
|
T014H - For COVID
|
|
---|---|---|
Specification
|
|
|
Sample type
|
Swab,Saliva and other liquid samples
|
|
Applicable Instrument
|
Tianlong Libex ,GeneRotex96 Nucleic Acid Extraction System and similar apparatus
|
|
Sample Storage
|
Fresh or stored at 4°C for up to 24 hours. For long-term storage, freezing at -20°C is recommended
|
Magnetic Beads method
Cat No.
|
Specification
|
Sample Type
|
Remark
|
---|---|---|---|
T014H
|
64T/Kit (pre-filled), 16T/Plate x 4 Plates
|
Swab and other liquid samples
|
|
T016H
|
20T/Box (Pre-filled) 1T/Strip
|
||
T050H
|
64T/Kit (pre-filled), 16T/Plate x 4 Plates
|
Swab, Saliva and other liquid samples
|
For all viruses(5.0)
|
T051H
|
40T/Kit (pre-filled), 10T/Plate x 4 Plates
|
||
T052H
|
20T/Kit (pre-filled), 5T/Plate x 4 Plates
|
||
T325H
|
96T/Kit (pre-filled) 16T/Plate x 6 Plates
|
Serum, Plasma, Urine, Swab, etc.
|
*For all viruses(4.0)*For PANA9600S
|
T041H
|
48T/Kit (pre-filled), 8T/Plate x 6 Plates
|
Whole blood, Serum, Plasma, Tissue fluid, Urine, Swab medium, etc.
|
*For all viruses(4.0)*For GeneRotex48
|
T322H
|
40T/Kit (pre-filled), 10T/Plate x 4 Plates
|
Serum, Plasma, Urine, Swab, etc.
|
For all viruses(4.0)
|
T323H
|
20T/Kit (pre-filled), 5T/Plate x 4 Plates
|
||
T324H
|
64T/Kit (pre-filled), 16T/Plate x 4 Plates
|
||
T038H
|
20T/Box (Pre-filled) 1T/Strip
|
||
T104H
|
20T/Box (Pre-filled) 1T/Strip
|
Serum; Plasma; Urine; Swab etc.
|
For all viruses
|
T111H
|
20T/Kit (pre-filled), 5T/Plate x 4 Plates
|
Serum, Plasma, Whole blood, etc.
|
For HCMV,EB
|
T112H
|
64T/Kit (pre-filled), 16T/Plate x 4 Plates
|
||
T123H
|
20T/Box (Pre-filled) 1T/Strip
|
||
T113H
|
20T/Kit (pre-filled), 5T/Plate x 4 Plates
|
Cytobrush collection medium, etc.
|
For HPV
|
T113H
|
20T/Kit (pre-filled), 5T/Plate x 4 Plates
|
||
T114H
|
64T/Kit (pre-filled), 16T/Plate x 4 Plates
|
||
T115H
|
20T/Box (Pre-filled) 1T/Strip
|
Spin column method
Cat.No
|
Specification
|
Sample Type
|
Remark
|
---|---|---|---|
T108H
|
32T/Kit (Non-pre-filled)
|
Serum, Plasma, Urine,Swab etc.
|
For all viruses
|
What is the difference between Gentier96 and Gentier48 ?
1.1 Sample throughout difference: Gentier96 can process maximum 96 samples per run, Gentier48 can process maximum 48 samples per run; 1.2 Fluorescence channel difference: Gentier96 E/R has 6/4 fluorescence channels separately, Gentier48 E/R has 4/2 fluorescence channels; 1.3 Light source location difference : The light source of Gentier96 is on the top,